Technical specifications

Rated permanent current Iu700A
Rated voltage690 - 690V
Overload release current setting700 - 700A
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementRocker lever
Motor drive optionalYes
Number of auxiliary contacts as normally open contact0
Adjustment range undelayed short-circuit release1400 - 8400A
With integrated under voltage releaseNo
Integrated earth fault protectionNo
With switched-off indicatorNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Motor drive integratedNo
Adjustment range short-term delayed short-circuit release1400 - 7000A
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Number of poles3

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH4-VEF700-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

700A

Rated voltage

690 .. 690V

Overload release current setting

700 .. 700A

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Type of control element

Rocker lever

Motor drive optional

Number of auxiliary contacts as normally open contact

0

Adjustment range undelayed short-circuit release

1400 .. 8400A

With integrated under voltage release

Integrated earth fault protection

With switched-off indicator

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Motor drive integrated

Adjustment range short-term delayed short-circuit release

1400 .. 7000A

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Number of poles

3