Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu125A
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release750 - 1250A
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitFrame clamp
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release0 - 0A
With switched-off indicatorNo
Number of poles3
Overload release current setting100 - 125A
Type of control elementRocker lever
Motor drive integratedNo
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
With integrated under voltage releaseNo
Rated voltage690 - 690V
Motor drive optionalNo
Number of auxiliary contacts as change-over contact0

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN1-A125-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

125A

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

750 .. 1250A

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Frame clamp

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

0 .. 0A

With switched-off indicator

Number of poles

3

Overload release current setting

100 .. 125A

Type of control element

Rocker lever

Motor drive integrated

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Complete device with protection unit

DIN rail (top hat rail) mounting optional

With integrated under voltage release

Rated voltage

690 .. 690V

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Related products