  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu80A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release480 - 800A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
Overload release current setting63 - 80A
Type of electrical connection of main circuitFrame clamp
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
With integrated under voltage releaseNo
Type of control elementRocker lever
Number of poles3
Motor drive integratedNo
Integrated earth fault protectionNo
With switched-off indicatorNo
Motor drive optionalNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
Degree of protection (IP)IP20
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as normally open contact0

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN1-A80-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

80A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

480 .. 800A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Overload release current setting

63 .. 80A

Type of electrical connection of main circuit

Frame clamp

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

With integrated under voltage release

Type of control element

Rocker lever

Number of poles

3

Motor drive integrated

Integrated earth fault protection

With switched-off indicator

Motor drive optional

Position of connection for main current circuit

Front side

Complete device with protection unit

Degree of protection (IP)

IP20

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as normally open contact

0