Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu20A
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting20 - 20A
Type of electrical connection of main circuitFrame clamp
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release350 - 350A
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Number of poles3
Motor drive integratedNo
Type of control elementRocker lever
Degree of protection (IP)IP20
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Motor drive optionalNo
With switched-off indicatorNo
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN1-AF20-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

20A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

20 .. 20A

Type of electrical connection of main circuit

Frame clamp

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

350 .. 350A

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Position of connection for main current circuit

Front side

Number of poles

3

Motor drive integrated

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Motor drive optional

With switched-off indicator

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.