  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu50A
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Type of electrical connection of main circuitFrame clamp
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Overload release current setting50 - 50A
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Number of poles3
With switched-off indicatorNo
Adjustment range undelayed short-circuit release6 - 10A
Type of control elementRocker lever
Complete device with protection unitYes
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Motor drive integratedNo
Motor drive optionalNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN1-AF50-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

50A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Type of electrical connection of main circuit

Frame clamp

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Overload release current setting

50 .. 50A

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Number of poles

3

With switched-off indicator

Adjustment range undelayed short-circuit release

6 .. 10A

Type of control element

Rocker lever

Complete device with protection unit

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Motor drive integrated

Motor drive optional