Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu175A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting175 - 175A
Type of electrical connection of main circuitFrame clamp
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release6 - 10A
Number of auxiliary contacts as normally closed contact0
With integrated under voltage releaseNo
Degree of protection (IP)IP20
Type of control elementRocker lever
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Complete device with protection unitYes
Number of poles4
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-4-AF175-BT-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

175A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

175 .. 175A

Type of electrical connection of main circuit

Frame clamp

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

6 .. 10A

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Complete device with protection unit

Number of poles

4

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Motor drive optional

Related products