Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu225A
Overload release current setting225 - 225A
Rated voltage690 - 690V
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitFrame clamp
DIN rail (top hat rail) mounting optionalYes
With integrated under voltage releaseNo
Number of poles4
Position of connection for main current circuitFront side
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Type of control elementRocker lever
Complete device with protection unitYes
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Motor drive integratedNo
Adjustment range undelayed short-circuit release6 - 10A
Motor drive optionalYes
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Adjustment range short-term delayed short-circuit release1500 - 2500A
Suitable for DIN rail (top hat rail) mountingNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-4-AF225-BT-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

225A

Overload release current setting

225 .. 225A

Rated voltage

690 .. 690V

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Frame clamp

DIN rail (top hat rail) mounting optional

With integrated under voltage release

Number of poles

4

Position of connection for main current circuit

Front side

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Type of control element

Rocker lever

Complete device with protection unit

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Motor drive integrated

Adjustment range undelayed short-circuit release

6 .. 10A

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Adjustment range short-term delayed short-circuit release

1500 .. 2500A

Suitable for DIN rail (top hat rail) mounting

Related products