Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu250A
Rated voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release1500 - 2500A
Overload release current setting250 - 250A
Adjustment range undelayed short-circuit release6 - 10A
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitFrame clamp
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
With integrated under voltage releaseNo
Number of poles4
Complete device with protection unitYes
Position of connection for main current circuitFront side
Motor drive integratedNo
Type of control elementRocker lever
Degree of protection (IP)IP20
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-4-AF250-BT-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

250A

Rated voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

1500 .. 2500A

Overload release current setting

250 .. 250A

Adjustment range undelayed short-circuit release

6 .. 10A

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Frame clamp

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

With integrated under voltage release

Number of poles

4

Complete device with protection unit

Position of connection for main current circuit

Front side

Motor drive integrated

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Motor drive optional

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.