Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Number of poles3
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Rated permanent current Iu125A
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release0 - 0A
With switched-off indicatorNo
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release750 - 1250A
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitFrame clamp
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Type of control elementRocker lever
Degree of protection (IP)IP20
Motor drive optionalYes
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Overload release current setting100 - 125A
Number of auxiliary contacts as change-over contact0

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-A125-BT-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Number of poles

3

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Rated permanent current Iu

125A

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

0 .. 0A

With switched-off indicator

Integrated earth fault protection

Adjustment range undelayed short-circuit release

750 .. 1250A

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Frame clamp

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Motor drive optional

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Overload release current setting

100 .. 125A

Number of auxiliary contacts as change-over contact

0

Related products