Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu160A
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Overload release current setting125 - 160A
Type of electrical connection of main circuitFrame clamp
Rated voltage690 - 690V
Number of poles3
Adjustment range undelayed short-circuit release960 - 1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Device constructionBuilt-in device fixed built-in technique
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release0 - 0A
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
Complete device with protection unitYes
Type of control elementRocker lever
Motor drive optionalYes
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Motor drive integratedNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-A160-BT-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

160A

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Overload release current setting

125 .. 160A

Type of electrical connection of main circuit

Frame clamp

Rated voltage

690 .. 690V

Number of poles

3

Adjustment range undelayed short-circuit release

960 .. 1600A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Device construction

Built-in device fixed built-in technique

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

0 .. 0A

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

Complete device with protection unit

Type of control element

Rocker lever

Motor drive optional

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Motor drive integrated

Related products