Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Rated voltage690 - 690V
Number of auxiliary contacts as normally closed contact0
Overload release current setting160 - 200A
Number of auxiliary contacts as normally open contact0
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitFrame clamp
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as change-over contact0
Number of poles3
Adjustment range undelayed short-circuit release1200 - 2000A
DIN rail (top hat rail) mounting optionalYes
With integrated under voltage releaseNo
Motor drive optionalYes
With switched-off indicatorNo
Type of control elementRocker lever
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
Degree of protection (IP)IP20
Motor drive integratedNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-A200-BT-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

200A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

160 .. 200A

Number of auxiliary contacts as normally open contact

0

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Frame clamp

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Adjustment range undelayed short-circuit release

1200 .. 2000A

DIN rail (top hat rail) mounting optional

With integrated under voltage release

Motor drive optional

With switched-off indicator

Type of control element

Rocker lever

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Position of connection for main current circuit

Front side

Integrated earth fault protection

Degree of protection (IP)

IP20

Motor drive integrated