Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu20A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Type of electrical connection of main circuitScrew connection
With switched-off indicatorNo
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
Number of poles3
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Type of control elementRocker lever
Overload release current setting15 - 20A
Complete device with protection unitYes
Motor drive integratedNo
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release350 - 350A
Degree of protection (IP)IP20
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-A20-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

20A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Type of electrical connection of main circuit

Screw connection

With switched-off indicator

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Number of poles

3

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Motor drive optional

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Overload release current setting

15 .. 20A

Complete device with protection unit

Motor drive integrated

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

350 .. 350A

Degree of protection (IP)

IP20

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Related products