Technical specifications

Rated permanent current Iu250A
Rated voltage690 - 690V
Overload release current setting200 - 250A
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release1500 - 2500A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitScrew connection
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Number of poles3
Number of auxiliary contacts as normally closed contact0
Complete device with protection unitYes
Type of control elementRocker lever
With integrated under voltage releaseNo
Degree of protection (IP)IP20
With switched-off indicatorNo
Motor drive optionalYes
Motor drive integratedNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-A250-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

250A

Rated voltage

690 .. 690V

Overload release current setting

200 .. 250A

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

1500 .. 2500A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Screw connection

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Complete device with protection unit

Type of control element

Rocker lever

With integrated under voltage release

Degree of protection (IP)

IP20

With switched-off indicator

Motor drive optional

Motor drive integrated