Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Rated permanent current Iu25A
Rated voltage690 - 690V
With integrated under voltage releaseNo
Overload release current setting20 - 25A
Complete device with protection unitYes
Position of connection for main current circuitFront side
With switched-off indicatorNo
Type of control elementRocker lever
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release350 - 350A
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release0 - 0A
Type of electrical connection of main circuitScrew connection
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Number of poles3
Motor drive optionalYes
Degree of protection (IP)IP20
Motor drive integratedNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-A25-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Rated permanent current Iu

25A

Rated voltage

690 .. 690V

With integrated under voltage release

Overload release current setting

20 .. 25A

Complete device with protection unit

Position of connection for main current circuit

Front side

With switched-off indicator

Type of control element

Rocker lever

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

350 .. 350A

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

0 .. 0A

Type of electrical connection of main circuit

Screw connection

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Motor drive optional

Degree of protection (IP)

IP20

Motor drive integrated

Related products