Technical specifications

Rated permanent current Iu63A
Rated voltage690 - 690V
Overload release current setting50 - 63A
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Type of electrical connection of main circuitScrew connection
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release380 - 630A
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
Number of poles3
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Complete device with protection unitYes
With integrated under voltage releaseNo
Type of control elementRocker lever
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
Motor drive integratedNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-A63-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

63A

Rated voltage

690 .. 690V

Overload release current setting

50 .. 63A

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Type of electrical connection of main circuit

Screw connection

Integrated earth fault protection

Adjustment range undelayed short-circuit release

380 .. 630A

DIN rail (top hat rail) mounting optional

With switched-off indicator

Number of poles

3

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Complete device with protection unit

With integrated under voltage release

Type of control element

Rocker lever

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Motor drive integrated