Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu80A
Rated voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release0 - 0A
Adjustment range undelayed short-circuit release480 - 800A
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Overload release current setting63 - 80A
Integrated earth fault protectionNo
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Number of poles3
Type of control elementRocker lever
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
Degree of protection (IP)IP20
Motor drive integratedNo
Complete device with protection unitYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-A80-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

80A

Rated voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

0 .. 0A

Adjustment range undelayed short-circuit release

480 .. 800A

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Overload release current setting

63 .. 80A

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Number of poles

3

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Motor drive optional

Degree of protection (IP)

IP20

Motor drive integrated

Complete device with protection unit

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.