Technical specifications

Adjustment range undelayed short-circuit release6 - 10A
Overload release current setting175 - 175A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Number of auxiliary contacts as normally closed contact0
Adjustment range short-term delayed short-circuit release0 - 0A
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementRocker lever
Rated permanent current Iu175A
With integrated under voltage releaseNo
Number of poles3
Complete device with protection unitYes
Motor drive optionalYes
Rated voltage690 - 690V
Degree of protection (IP)IP20
Motor drive integratedNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-AF175-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range undelayed short-circuit release

6 .. 10A

Overload release current setting

175 .. 175A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Number of auxiliary contacts as normally closed contact

0

Adjustment range short-term delayed short-circuit release

0 .. 0A

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Integrated earth fault protection

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Type of control element

Rocker lever

Rated permanent current Iu

175A

With integrated under voltage release

Number of poles

3

Complete device with protection unit

Motor drive optional

Rated voltage

690 .. 690V

Degree of protection (IP)

IP20

Motor drive integrated

Related products