Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu20A
Overload release current setting20 - 20A
Adjustment range undelayed short-circuit release350 - 350A
Adjustment range short-term delayed short-circuit release0 - 0A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Integrated earth fault protectionNo
Type of electrical connection of main circuitFrame clamp
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
With integrated under voltage releaseNo
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Number of poles3
Type of control elementRocker lever
Position of connection for main current circuitFront side
Motor drive integratedNo
Complete device with protection unitYes
Motor drive optionalYes
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-AF20-BT-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

20A

Overload release current setting

20 .. 20A

Adjustment range undelayed short-circuit release

350 .. 350A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Integrated earth fault protection

Type of electrical connection of main circuit

Frame clamp

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

With switched-off indicator

With integrated under voltage release

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

Motor drive integrated

Complete device with protection unit

Motor drive optional

Degree of protection (IP)

IP20