Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release6 - 10A
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release0 - 0A
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitFrame clamp
Rated permanent current Iu225A
Number of auxiliary contacts as normally open contact0
Overload release current setting225 - 225A
Number of poles3
With switched-off indicatorNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Complete device with protection unitYes
With integrated under voltage releaseNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Motor drive integratedNo
Degree of protection (IP)IP20
DIN rail (top hat rail) mounting optionalYes
Type of control elementRocker lever

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-AF225-BT-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

6 .. 10A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

0 .. 0A

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Frame clamp

Rated permanent current Iu

225A

Number of auxiliary contacts as normally open contact

0

Overload release current setting

225 .. 225A

Number of poles

3

With switched-off indicator

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit

With integrated under voltage release

Motor drive optional

Position of connection for main current circuit

Front side

Motor drive integrated

Degree of protection (IP)

IP20

DIN rail (top hat rail) mounting optional

Type of control element

Rocker lever