Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu250A
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release6 - 10A
Overload release current setting250 - 250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release0 - 0A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitFrame clamp
With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
Number of poles3
Motor drive optionalYes
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
Number of auxiliary contacts as normally open contact0
Type of control elementRocker lever
Motor drive integratedNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-AF250-BT-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

250A

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

6 .. 10A

Overload release current setting

250 .. 250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Frame clamp

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

Motor drive optional

With switched-off indicator

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Type of control element

Rocker lever

Motor drive integrated

Position of connection for main current circuit

Front side

Complete device with protection unit

Degree of protection (IP)

IP20

Related products