Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu12A
Overload release current setting0 - 0A
Adjustment range undelayed short-circuit release7 - 12A
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
Motor drive integratedNo
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Type of control elementRocker lever
Complete device with protection unitYes
Number of poles3
Degree of protection (IP)IP20
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-S12-CNA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

12A

Overload release current setting

0 .. 0A

Adjustment range undelayed short-circuit release

7 .. 12A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

With switched-off indicator

Motor drive integrated

Position of connection for main current circuit

Front side

With integrated under voltage release

Type of control element

Rocker lever

Complete device with protection unit

Number of poles

3

Degree of protection (IP)

IP20

Motor drive optional