Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Rated permanent current Iu18A
Adjustment range short-term delayed short-circuit release0 - 0A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release7 - 12A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitScrew connection
DIN rail (top hat rail) mounting optionalYes
Rated voltage690 - 690V
With switched-off indicatorNo
Number of auxiliary contacts as normally closed contact0
Number of poles3
With integrated under voltage releaseNo
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Complete device with protection unitYes
Integrated earth fault protectionNo
Degree of protection (IP)IP20
Type of control elementRocker lever
Motor drive optionalYes
Overload release current setting0 - 0A
Position of connection for main current circuitFront side

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-S18-CNA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Rated permanent current Iu

18A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

7 .. 12A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Screw connection

DIN rail (top hat rail) mounting optional

Rated voltage

690 .. 690V

With switched-off indicator

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

With integrated under voltage release

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit

Integrated earth fault protection

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Motor drive optional

Overload release current setting

0 .. 0A

Position of connection for main current circuit

Front side

Related products