Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu26A
Overload release current setting0 - 0A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Rated voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release0 - 0A
Adjustment range undelayed short-circuit release8 - 13A
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitScrew connection
Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Number of poles3
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Position of connection for main current circuitFront side
Motor drive integratedNo
Motor drive optionalYes
Complete device with protection unitYes
Degree of protection (IP)IP20
Type of control elementRocker lever

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-S26-CNA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

26A

Overload release current setting

0 .. 0A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Rated voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

0 .. 0A

Adjustment range undelayed short-circuit release

8 .. 13A

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Screw connection

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Number of poles

3

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Position of connection for main current circuit

Front side

Motor drive integrated

Motor drive optional

Complete device with protection unit

Degree of protection (IP)

IP20

Type of control element

Rocker lever