Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of poles3
Overload release current setting0 - 0A
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu90A
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Type of control elementRocker lever
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Position of connection for main current circuitFront side
With switched-off indicatorNo
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Type of electrical connection of main circuitFrame clamp
Motor drive optionalYes
Integrated earth fault protectionNo
With under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release0 - 0A
Adjustment range undelayed short-circuit release180 - 1260A
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-SE90-BT-CNA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of poles

3

Overload release current setting

0 .. 0A

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

90A

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Position of connection for main current circuit

Front side

With switched-off indicator

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Type of electrical connection of main circuit

Frame clamp

Motor drive optional

Integrated earth fault protection

With under voltage release

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

0 .. 0A

Adjustment range undelayed short-circuit release

180 .. 1260A

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.