Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu500A
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release1000 - 4000A
Type of control elementRocker lever
Motor drive integratedNo
Motor drive optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting500 - 500A
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalNo
Rated voltage690 - 690V
Number of poles3
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitScrew connection

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-AEF500-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

500A

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Adjustment range undelayed short-circuit release

1000 .. 4000A

Type of control element

Rocker lever

Motor drive integrated

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

500 .. 500A

With switched-off indicator

DIN rail (top hat rail) mounting optional

Rated voltage

690 .. 690V

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Screw connection