Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release400 - 4000A
Overload release current setting200 - 400A
Type of electrical connection of main circuitScrew connection
Adjustment range undelayed short-circuit release800 - 4400A
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Rated permanent current Iu400A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Number of poles3
Complete device with protection unitYes
Motor drive integratedNo
Degree of protection (IP)IP20
With switched-off indicatorNo
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
Type of control elementRocker lever

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-VE400-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release

400 .. 4000A

Overload release current setting

200 .. 400A

Type of electrical connection of main circuit

Screw connection

Adjustment range undelayed short-circuit release

800 .. 4400A

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Rated permanent current Iu

400A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

With integrated under voltage release

Number of poles

3

Complete device with protection unit

Motor drive integrated

Degree of protection (IP)

IP20

With switched-off indicator

Motor drive optional

DIN rail (top hat rail) mounting optional

Type of control element

Rocker lever

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.