Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu350A
Overload release current setting350 - 350A
Adjustment range short-term delayed short-circuit release700 - 3500A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release700 - 3850A
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as change-over contact0
Number of poles3
Type of control elementRocker lever
With integrated under voltage releaseNo
With switched-off indicatorNo
Position of connection for main current circuitFront side
Motor drive integratedNo
Degree of protection (IP)IP20
Motor drive optionalYes
Complete device with protection unitYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-VEF350-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

350A

Overload release current setting

350 .. 350A

Adjustment range short-term delayed short-circuit release

700 .. 3500A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

700 .. 3850A

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Type of control element

Rocker lever

With integrated under voltage release

With switched-off indicator

Position of connection for main current circuit

Front side

Motor drive integrated

Degree of protection (IP)

IP20

Motor drive optional

Complete device with protection unit

Related products