Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Type of electrical connection of main circuitScrew connection
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release1000 - 4000A
DIN rail (top hat rail) mounting optionalNo
Position of connection for main current circuitFront side
Rated voltage690 - 690V
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Overload release current setting500 - 500A
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release750 - 3500A
Rated permanent current Iu500A
Type of control elementRocker lever
Motor drive optionalYes
Number of poles3
Complete device with protection unitYes
Motor drive integratedNo
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-VEF500-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Type of electrical connection of main circuit

Screw connection

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

1000 .. 4000A

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

Rated voltage

690 .. 690V

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Overload release current setting

500 .. 500A

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

750 .. 3500A

Rated permanent current Iu

500A

Type of control element

Rocker lever

Motor drive optional

Number of poles

3

Complete device with protection unit

Motor drive integrated

Degree of protection (IP)

IP20

Related products