Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu600A
Overload release current setting600 - 600A
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release1200 - 4800A
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Type of control elementRocker lever
With integrated under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release900 - 4200A
Motor drive optionalYes
Motor drive integratedNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
With switched-off indicatorNo
Number of poles3
Complete device with protection unitYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-VEF600-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

600A

Overload release current setting

600 .. 600A

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

1200 .. 4800A

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Type of control element

Rocker lever

With integrated under voltage release

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

900 .. 4200A

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

With switched-off indicator

Number of poles

3

Complete device with protection unit

Related products