Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release0 - 0A
Adjustment range undelayed short-circuit release1200 - 7200A
Rated voltage690 - 690V
Type of electrical connection of main circuitScrew connection
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz37kA
Device constructionBuilt-in device fixed built-in technique
Overload release current setting600 - 600A
Suitable for DIN rail (top hat rail) mountingNo
Rated permanent current Iu600A
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Number of poles3
Complete device with protection unitYes
Number of auxiliary contacts as normally closed contact0
Type of control elementRocker lever
Position of connection for main current circuitFront side
Motor drive integratedNo
Degree of protection (IP)IP20
Motor drive optionalYes
With integrated under voltage releaseNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN4-AEF600-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release

0 .. 0A

Adjustment range undelayed short-circuit release

1200 .. 7200A

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Screw connection

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

37kA

Device construction

Built-in device fixed built-in technique

Overload release current setting

600 .. 600A

Suitable for DIN rail (top hat rail) mounting

Rated permanent current Iu

600A

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Complete device with protection unit

Number of auxiliary contacts as normally closed contact

0

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

Motor drive integrated

Degree of protection (IP)

IP20

Motor drive optional

With integrated under voltage release

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.