Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu800A
Rated voltage690 - 690V
Overload release current setting400 - 800A
With switched-off indicatorNo
Adjustment range undelayed short-circuit release1600 - 9600A
Adjustment range short-term delayed short-circuit release800 - 8000A
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitScrew connection
Integrated earth fault protectionNo
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
Number of poles3
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz37kA
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
Degree of protection (IP)IP20
Type of control elementRocker lever
Position of connection for main current circuitFront side
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN4-VE800-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

800A

Rated voltage

690 .. 690V

Overload release current setting

400 .. 800A

With switched-off indicator

Adjustment range undelayed short-circuit release

1600 .. 9600A

Adjustment range short-term delayed short-circuit release

800 .. 8000A

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Screw connection

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Device construction

Built-in device fixed built-in technique

Motor drive optional

Number of poles

3

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

37kA

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Number of auxiliary contacts as change-over contact

0