Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu900A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz37kA
Rated voltage690 - 690V
DIN rail (top hat rail) mounting optionalYes
Adjustment range short-term delayed short-circuit release1800 - 9000A
Number of auxiliary contacts as normally closed contact0
Adjustment range undelayed short-circuit release1800 - 10800A
Integrated earth fault protectionNo
Overload release current setting900 - 900A
With switched-off indicatorNo
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Motor drive optionalYes
Motor drive integratedNo
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitScrew connection
Type of control elementRocker lever
Complete device with protection unitYes
Degree of protection (IP)IP20
Number of poles3

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN4-VEF900-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

900A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

37kA

Rated voltage

690 .. 690V

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

1800 .. 9000A

Number of auxiliary contacts as normally closed contact

0

Adjustment range undelayed short-circuit release

1800 .. 10800A

Integrated earth fault protection

Overload release current setting

900 .. 900A

With switched-off indicator

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Motor drive optional

Motor drive integrated

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Screw connection

Type of control element

Rocker lever

Complete device with protection unit

Degree of protection (IP)

IP20

Number of poles

3

Related products