Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth75mm
Voltage typeAC
Rated voltage400V
Rated current32A
Suitable for flush-mounted installationNo
Rated insulation voltage Ui440V
Number of protected poles3
Current limiting class3
Degree of protection (IP)IP20
Width in number of modular spacings4.5
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired2.5 - 50mm²
Frequency50 - 60Hz
Pollution degree2
Connectable conductor cross section solid-core2.5 - 50mm²
Release characteristicB
Over voltage category3
Ambient temperature during operating-25 - 55°C
Number of poles (total)3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

PLHT-B32/3

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75mm

Voltage type

AC

Rated voltage

400V

Rated current

32A

Suitable for flush-mounted installation

Rated insulation voltage Ui

440V

Number of protected poles

3

Current limiting class

3

Degree of protection (IP)

IP20

Width in number of modular spacings

4.5

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Frequency

50 .. 60Hz

Pollution degree

2

Connectable conductor cross section solid-core

2.5 .. 50mm²

Release characteristic

B

Over voltage category

3

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

3

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA