Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Cable type
Other
Duplex
No
Conductor material
Other
AWG size
20
Diameter conductor
1.5mm
Nominal cross section conductor
0.5mm²
Conductor category
Class 2 = stranded
Conductor surface
Bare
Stranding element
Pairs
Number of stranding elements
26
Screen over stranding element
Foil
Specification core insulation
Other
Core identification
Colour
Core identification according to HD 308 S2
No
Screen over stranding
None
Longitudinal water blocking cable
No
Suitable for underground installation
No
Radial water blocking cable
Yes
Material core insulation
Other
Number of cores
4
Stranding
Bundle
Protective sheath
Other
Colour outer sheath
Black
Material outer sheath
Polyvinyl chloride (PVC)
Number of sheath layers
0
Flame retardant according to IEC 60332-3-22 (Cat A)
No
Specification material outer sheath
Other
Armouring/reinforcement
None
Flame retardant according to IEC 60332-3-23 (Cat B)
No
Flame retardant according to IEC 60332-1-2
No
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
No
Halogen free (according to IEC 60754-2)
No
Material reinforcement
Other
Approved type of underground installation
Other
Low smoke (according to IEC 61034-2)
No
Cable geometry
Round
Halogen free according to IEC 60754-1
No
Flame retardant according to IEC 60332-3-24 (Cat C)
No
Flame retardant according to IEC 60332-3-25 (Cat D)
No
Permitted cable outer temperature during assembling/handling
-25 - 70°C
Permitted cable outer temperature after assembling without vibration
-25 - 70°C
Category
Other
NVP value
66.5%
UV resistant
No
Certified for shipboard application
No
Suitable as telephone cable
No
Suitable as computer data cable
No
Suitable as signalling cable
Yes
Suitable for use as security alarm cable
No
Drain wire
No
With rip cord
No
Cable width approx.
5.6mm
Cable height approx.
76.923mm
Characteristic impedance
100Ohm
Nominal voltage U
24V
With rodent protection
No
Compatible with Grade2TV according to XP-C 90-483
No
Compatible with Grade3TV according to XP-C 90-483
No
Smoke development class according to EN 13501-6
None
Circuit integrity according to IEC 60331-23
No
Euro class acidity according to EN 13501-6
None
Euro class flaming droplets/particles according to EN 13501-6
None
Min. permitted bending radius, moving application/free movement
0mm
Oil resistant (according to EN 60811-404)
Yes
Min. permitted bending radius, stationary application/permanent installation
64mm
Outer diameter approx.
11mm
Min. permitted bending radius, moving application with forced guidance
0mm
Reaction-to-fire class according to EN 13501-6
None
Halogen free according to IEC 60754-3
No
From same serie
SWD4-10LR4P-2S

Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Cable type
Other
Duplex
Conductor material
Other
AWG size
20
Diameter conductor
1.5mm
Nominal cross section conductor
0.5mm²
Conductor category
Class 2 = stranded
Conductor surface
Bare
Stranding element
Pairs
Number of stranding elements
26
Screen over stranding element
Foil
Specification core insulation
Other
Core identification
Colour
Core identification according to HD 308 S2
Screen over stranding
None
Longitudinal water blocking cable
Suitable for underground installation
Radial water blocking cable
Material core insulation
Other
Number of cores
4
Stranding
Bundle
Protective sheath
Other
Colour outer sheath
Black
Material outer sheath
Polyvinyl chloride (PVC)
Number of sheath layers
0
Flame retardant according to IEC 60332-3-22 (Cat A)
Specification material outer sheath
Other
Armouring/reinforcement
None
Flame retardant according to IEC 60332-3-23 (Cat B)
Flame retardant according to IEC 60332-1-2
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
Halogen free (according to IEC 60754-2)
Material reinforcement
Other
Approved type of underground installation
Other
Low smoke (according to IEC 61034-2)
Cable geometry
Round
Halogen free according to IEC 60754-1
Flame retardant according to IEC 60332-3-24 (Cat C)
Flame retardant according to IEC 60332-3-25 (Cat D)
Permitted cable outer temperature during assembling/handling
-25 .. 70°C
Permitted cable outer temperature after assembling without vibration
-25 .. 70°C
Category
Other
NVP value
66.5%
UV resistant
Certified for shipboard application
Suitable as telephone cable
Suitable as computer data cable
Suitable as signalling cable
Suitable for use as security alarm cable
Drain wire
With rip cord
Cable width approx.
5.6mm
Cable height approx.
76.923mm
Characteristic impedance
100Ohm
Nominal voltage U
24V
With rodent protection
Compatible with Grade2TV according to XP-C 90-483
Compatible with Grade3TV according to XP-C 90-483
Smoke development class according to EN 13501-6
None
Circuit integrity according to IEC 60331-23
Euro class acidity according to EN 13501-6
None
Euro class flaming droplets/particles according to EN 13501-6
None
Min. permitted bending radius, moving application/free movement
0mm
Oil resistant (according to EN 60811-404)
Min. permitted bending radius, stationary application/permanent installation
64mm
Outer diameter approx.
11mm
Min. permitted bending radius, moving application with forced guidance
0mm
Reaction-to-fire class according to EN 13501-6
None
Halogen free according to IEC 60754-3
From same serie
We use cookies to enhance your experience.