Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Duplex
No
Conductor material
Other
Number of cores
4
Conductor category
Class 2 = stranded
Cable type
Other
Number of stranding elements
26
Diameter conductor
1.5mm
AWG size
20
Nominal cross section conductor
0.5mm²
Specification core insulation
Other
Core identification according to HD 308 S2
No
Specification material outer sheath
Other
Material core insulation
Other
Stranding element
Pairs
Screen over stranding element
Foil
Conductor surface
Bare
Flame retardant according to IEC 60332-3-22 (Cat A)
No
Approved type of underground installation
Other
Screen over stranding
None
Protective sheath
Other
Material outer sheath
Polyvinyl chloride (PVC)
Stranding
Bundle
Material reinforcement
Other
Radial water blocking cable
Yes
Longitudinal water blocking cable
Yes
Flame retardant according to IEC 60332-1-2
No
Cable geometry
Round
Halogen free (according to IEC 60754-2)
No
Colour outer sheath
Black
Euro class acidity according to EN 13501-6
None
Armouring/reinforcement
None
Low smoke (according to IEC 61034-2)
No
Flame retardant according to IEC 60332-3-23 (Cat B)
No
Smoke development class according to EN 13501-6
None
Halogen free according to IEC 60754-3
No
Flame retardant according to IEC 60332-3-24 (Cat C)
No
Core identification
Colour
Flame retardant according to IEC 60332-3-25 (Cat D)
No
Halogen free according to IEC 60754-1
No
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
No
Min. permitted bending radius, moving application with forced guidance
0mm
Oil resistant (according to EN 60811-404)
Yes
Euro class flaming droplets/particles according to EN 13501-6
None
Suitable for underground installation
No
Outer diameter approx.
11mm
Reaction-to-fire class according to EN 13501-6
None
Min. permitted bending radius, moving application/free movement
0mm
Min. permitted bending radius, stationary application/permanent installation
64mm
Circuit integrity according to IEC 60331-23
No
Number of sheath layers
0
Permitted cable outer temperature during assembling/handling
-25 - 70°C
Permitted cable outer temperature after assembling without vibration
-25 - 70°C
Category
Other
NVP value
66.5%
UV resistant
Yes
Suitable as telephone cable
No
Certified for shipboard application
No
Suitable as computer data cable
No
Suitable as signalling cable
Yes
Suitable for use as security alarm cable
No
With rip cord
No
Drain wire
No
Cable width approx.
5.6mm
Characteristic impedance
100Ohm
Cable height approx.
76.923mm
With rodent protection
No
Nominal voltage U
24V
Compatible with Grade3TV according to XP-C 90-483
No
Compatible with Grade2TV according to XP-C 90-483
No
From same serie
SWD4-10LR4P-S

Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Duplex
Conductor material
Other
Number of cores
4
Conductor category
Class 2 = stranded
Cable type
Other
Number of stranding elements
26
Diameter conductor
1.5mm
AWG size
20
Nominal cross section conductor
0.5mm²
Specification core insulation
Other
Core identification according to HD 308 S2
Specification material outer sheath
Other
Material core insulation
Other
Stranding element
Pairs
Screen over stranding element
Foil
Conductor surface
Bare
Flame retardant according to IEC 60332-3-22 (Cat A)
Approved type of underground installation
Other
Screen over stranding
None
Protective sheath
Other
Material outer sheath
Polyvinyl chloride (PVC)
Stranding
Bundle
Material reinforcement
Other
Radial water blocking cable
Longitudinal water blocking cable
Flame retardant according to IEC 60332-1-2
Cable geometry
Round
Halogen free (according to IEC 60754-2)
Colour outer sheath
Black
Euro class acidity according to EN 13501-6
None
Armouring/reinforcement
None
Low smoke (according to IEC 61034-2)
Flame retardant according to IEC 60332-3-23 (Cat B)
Smoke development class according to EN 13501-6
None
Halogen free according to IEC 60754-3
Flame retardant according to IEC 60332-3-24 (Cat C)
Core identification
Colour
Flame retardant according to IEC 60332-3-25 (Cat D)
Halogen free according to IEC 60754-1
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
Min. permitted bending radius, moving application with forced guidance
0mm
Oil resistant (according to EN 60811-404)
Euro class flaming droplets/particles according to EN 13501-6
None
Suitable for underground installation
Outer diameter approx.
11mm
Reaction-to-fire class according to EN 13501-6
None
Min. permitted bending radius, moving application/free movement
0mm
Min. permitted bending radius, stationary application/permanent installation
64mm
Circuit integrity according to IEC 60331-23
Number of sheath layers
0
Permitted cable outer temperature during assembling/handling
-25 .. 70°C
Permitted cable outer temperature after assembling without vibration
-25 .. 70°C
Category
Other
NVP value
66.5%
UV resistant
Suitable as telephone cable
Certified for shipboard application
Suitable as computer data cable
Suitable as signalling cable
Suitable for use as security alarm cable
With rip cord
Drain wire
Cable width approx.
5.6mm
Characteristic impedance
100Ohm
Cable height approx.
76.923mm
With rodent protection
Nominal voltage U
24V
Compatible with Grade3TV according to XP-C 90-483
Compatible with Grade2TV according to XP-C 90-483
From same serie
We use cookies to enhance your experience.