Skip to content
Aleta.hr
Announcement

Registration is currently available to business customers only (B2B).

Details

  • •Supply cable for SWD modules IP67 EU6E,EU8E, 1m
  • •Cables
  • •Data and communication cable
  • •Minimum order quantity: 1 pcs
  • •EATON

Technical specifications

Cable typeOther
Diameter conductor1.5mm
Core identification according to HD 308 S2No
StrandingBundle
Specification core insulationOther
Screen over strandingNone
AWG size20
DuplexNo
Nominal cross section conductor0.5mm²
Conductor categoryClass 2 = stranded
Longitudinal water blocking cableNo
Number of cores4
Stranding elementPairs
Conductor materialOther
Material core insulationOther
Screen over stranding elementFoil
Conductor surfaceBare
Flame retardant according to IEC 60332-3-23 (Cat B)No
Number of stranding elements26
Flame retardant according to IEC 60332-3-24 (Cat C)No
Core identificationColour
Suitable for underground installationNo
Min. permitted bending radius, stationary application/permanent installation64mm
Halogen free (according to IEC 60754-2)No
Radial water blocking cableYes
Flame retardant according to IEC 60332-1-2No
Reaction-to-fire class according to EN 13501-6None
Euro class acidity according to EN 13501-6None
Armouring/reinforcementNone
Number of sheath layers0
Flame retardant according to IEC 60332-3-22 (Cat A)No
Oil resistant (according to EN 60811-404)Yes
Material outer sheathPolyvinyl chloride (PVC)
Circuit integrity according to IEC 60331-23No
Min. permitted bending radius, moving application/free movement0mm
Smoke development class according to EN 13501-6None
Specification material outer sheathOther
Colour outer sheathBlack
Approved type of underground installationOther
Halogen free according to IEC 60754-3No
Euro class flaming droplets/particles according to EN 13501-6None
Protective sheathOther
Material reinforcementOther
Min. permitted bending radius, moving application with forced guidance0mm
Flame retardant according to IEC 60332-3-21 (Cat A F/R)No
Low smoke (according to IEC 61034-2)No
Flame retardant according to IEC 60332-3-25 (Cat D)No
Outer diameter approx.11mm
Halogen free according to IEC 60754-1No
Cable geometryRound
Permitted cable outer temperature after assembling without vibration-25 - 70°C
CategoryOther
Permitted cable outer temperature during assembling/handling-25 - 70°C
Certified for shipboard applicationNo
Suitable as telephone cableNo
Suitable as computer data cableNo
NVP value66.5%
Suitable as signalling cableYes
Suitable for use as security alarm cableNo
Drain wireNo
Cable width approx.5.6mm
Cable height approx.51.282mm
With rip cordNo
Characteristic impedance100Ohm
Nominal voltage U24V
With rodent protectionNo
Compatible with Grade2TV according to XP-C 90-483No
Compatible with Grade3TV according to XP-C 90-483No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as