Aleta.hr
Announcement

Registration is currently available to business customers only (B2B).

Details

  • •Supply cable for SWD modules IP67 EU6E, EU8E, 2
  • •Cables
  • •Data and communication cable
  • •Minimum order quantity: 1 pcs
  • •EATON

Technical specifications

Core identificationColour
Stranding elementPairs
Material core insulationOther
Characteristic impedance100Ohm
Diameter conductor1.5mm
Conductor categoryClass 2 = stranded
Screen over strandingNone
Nominal voltage U24V
Screen over stranding elementFoil
UV resistantYes
CategoryOther
Material outer sheathPolyvinyl chloride (PVC)
Armouring/reinforcementNone
Drain wireNo
Suitable for underground installationNo
With rodent protectionNo
Radial water blocking cableYes
Oil resistant (according to EN 60811-404)Yes
Low smoke (according to IEC 61034-2)No
Number of stranding elements26
Cable height approx.307.692mm
StrandingBundle
Smoke development class according to EN 13501-6None
Reaction-to-fire class according to EN 13501-6None
Permitted cable outer temperature during assembling/handling-25 - 70°C
Protective sheathOther
Cable width approx.5.6mm
Outer diameter approx.11mm
NVP value66.5%
Permitted cable outer temperature after assembling without vibration-25 - 70°C
Euro class flaming droplets/particles according to EN 13501-6None
Conductor surfaceBare
Number of cores4
Longitudinal water blocking cableYes
Min. permitted bending radius, moving application with forced guidance0mm
Euro class acidity according to EN 13501-6None
AWG size20
Min. permitted bending radius, moving application/free movement0mm
Halogen free (according to IEC 60754-2)No
Cable geometryRound
Flame retardant according to IEC 60332-3-24 (Cat C)No
Material reinforcementOther
Specification core insulationOther
Halogen free according to IEC 60754-1No
Suitable as telephone cableNo
Suitable as computer data cableNo
Flame retardant according to IEC 60332-1-2No
Specification material outer sheathOther
Flame retardant according to IEC 60332-3-23 (Cat B)No
Circuit integrity according to IEC 60331-23No
Flame retardant according to IEC 60332-3-21 (Cat A F/R)No
Core identification according to HD 308 S2No
Flame retardant according to IEC 60332-3-22 (Cat A)No
Approved type of underground installationOther
Suitable as signalling cableYes
Flame retardant according to IEC 60332-3-25 (Cat D)No
Certified for shipboard applicationNo
Halogen free according to IEC 60754-3No
Min. permitted bending radius, stationary application/permanent installation64mm
Number of sheath layers0
Suitable for use as security alarm cableNo
With rip cordNo
DuplexNo
Compatible with Grade2TV according to XP-C 90-483No
Compatible with Grade3TV according to XP-C 90-483No
Nominal cross section conductor0.5mm²
Cable typeOther
Colour outer sheathBlack
Conductor materialOther
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as