Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Cable type
Other
Duplex
No
Stranding element
Pairs
Core identification according to HD 308 S2
No
Core identification
Colour
Number of cores
4
Number of stranding elements
26
Conductor surface
Bare
Specification core insulation
Other
Conductor category
Class 2 = stranded
Conductor material
Other
AWG size
20
Diameter conductor
1.5mm
Material core insulation
Other
Nominal cross section conductor
0.5mm²
Approved type of underground installation
Other
Stranding
Bundle
Screen over stranding
None
Material outer sheath
Polyvinyl chloride (PVC)
Protective sheath
Other
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
No
Flame retardant according to IEC 60332-3-22 (Cat A)
No
Flame retardant according to IEC 60332-3-23 (Cat B)
No
Flame retardant according to IEC 60332-1-2
No
Screen over stranding element
Foil
Specification material outer sheath
Other
Longitudinal water blocking cable
No
Halogen free according to IEC 60754-3
No
Suitable for underground installation
No
Halogen free according to IEC 60754-1
No
Halogen free (according to IEC 60754-2)
No
Flame retardant according to IEC 60332-3-25 (Cat D)
No
Number of sheath layers
0
Reaction-to-fire class according to EN 13501-6
None
Cable geometry
Round
Min. permitted bending radius, moving application/free movement
0mm
Material reinforcement
Other
Colour outer sheath
Black
Circuit integrity according to IEC 60331-23
No
Armouring/reinforcement
None
Radial water blocking cable
Yes
Min. permitted bending radius, moving application with forced guidance
0mm
Oil resistant (according to EN 60811-404)
Yes
Euro class acidity according to EN 13501-6
None
Flame retardant according to IEC 60332-3-24 (Cat C)
No
Outer diameter approx.
11mm
Min. permitted bending radius, stationary application/permanent installation
64mm
Smoke development class according to EN 13501-6
None
Low smoke (according to IEC 61034-2)
No
Euro class flaming droplets/particles according to EN 13501-6
None
Permitted cable outer temperature after assembling without vibration
-25 - 70°C
Category
Other
Permitted cable outer temperature during assembling/handling
-25 - 70°C
NVP value
66.5%
UV resistant
No
Certified for shipboard application
No
Suitable as telephone cable
No
Suitable as signalling cable
Yes
Compatible with Grade2TV according to XP-C 90-483
No
With rodent protection
No
Characteristic impedance
100Ohm
Suitable as computer data cable
No
With rip cord
No
Compatible with Grade3TV according to XP-C 90-483
No
Nominal voltage U
24V
Cable height approx.
51.282mm
Suitable for use as security alarm cable
No
Drain wire
No
Cable width approx.
5.6mm
From same serie
SWD4-2LR4P-S

Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Cable type
Other
Duplex
Stranding element
Pairs
Core identification according to HD 308 S2
Core identification
Colour
Number of cores
4
Number of stranding elements
26
Conductor surface
Bare
Specification core insulation
Other
Conductor category
Class 2 = stranded
Conductor material
Other
AWG size
20
Diameter conductor
1.5mm
Material core insulation
Other
Nominal cross section conductor
0.5mm²
Approved type of underground installation
Other
Stranding
Bundle
Screen over stranding
None
Material outer sheath
Polyvinyl chloride (PVC)
Protective sheath
Other
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
Flame retardant according to IEC 60332-3-22 (Cat A)
Flame retardant according to IEC 60332-3-23 (Cat B)
Flame retardant according to IEC 60332-1-2
Screen over stranding element
Foil
Specification material outer sheath
Other
Longitudinal water blocking cable
Halogen free according to IEC 60754-3
Suitable for underground installation
Halogen free according to IEC 60754-1
Halogen free (according to IEC 60754-2)
Flame retardant according to IEC 60332-3-25 (Cat D)
Number of sheath layers
0
Reaction-to-fire class according to EN 13501-6
None
Cable geometry
Round
Min. permitted bending radius, moving application/free movement
0mm
Material reinforcement
Other
Colour outer sheath
Black
Circuit integrity according to IEC 60331-23
Armouring/reinforcement
None
Radial water blocking cable
Min. permitted bending radius, moving application with forced guidance
0mm
Oil resistant (according to EN 60811-404)
Euro class acidity according to EN 13501-6
None
Flame retardant according to IEC 60332-3-24 (Cat C)
Outer diameter approx.
11mm
Min. permitted bending radius, stationary application/permanent installation
64mm
Smoke development class according to EN 13501-6
None
Low smoke (according to IEC 61034-2)
Euro class flaming droplets/particles according to EN 13501-6
None
Permitted cable outer temperature after assembling without vibration
-25 .. 70°C
Category
Other
Permitted cable outer temperature during assembling/handling
-25 .. 70°C
NVP value
66.5%
UV resistant
Certified for shipboard application
Suitable as telephone cable
Suitable as signalling cable
Compatible with Grade2TV according to XP-C 90-483
With rodent protection
Characteristic impedance
100Ohm
Suitable as computer data cable
With rip cord
Compatible with Grade3TV according to XP-C 90-483
Nominal voltage U
24V
Cable height approx.
51.282mm
Suitable for use as security alarm cable
Drain wire
Cable width approx.
5.6mm
From same serie