Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Conductor surface
Bare
AWG size
20
Conductor category
Class 2 = stranded
Conductor material
Other
Core identification according to HD 308 S2
No
Cable type
Other
Material core insulation
Other
Screen over stranding element
Foil
Diameter conductor
1.5mm
Longitudinal water blocking cable
Yes
Radial water blocking cable
Yes
Approved type of underground installation
Other
Stranding
Bundle
Screen over stranding
None
Number of stranding elements
26
Stranding element
Pairs
Suitable for underground installation
No
Material outer sheath
Polyvinyl chloride (PVC)
Protective sheath
Other
Cable geometry
Round
Colour outer sheath
Black
Armouring/reinforcement
None
Flame retardant according to IEC 60332-3-24 (Cat C)
No
Number of cores
4
Flame retardant according to IEC 60332-3-23 (Cat B)
No
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
No
Material reinforcement
Other
Duplex
No
Nominal cross section conductor
0.5mm²
Flame retardant according to IEC 60332-1-2
No
Halogen free according to IEC 60754-1
No
Low smoke (according to IEC 61034-2)
No
Halogen free (according to IEC 60754-2)
No
Core identification
Colour
Euro class acidity according to EN 13501-6
None
Halogen free according to IEC 60754-3
No
Number of sheath layers
0
Smoke development class according to EN 13501-6
None
Flame retardant according to IEC 60332-3-22 (Cat A)
No
Flame retardant according to IEC 60332-3-25 (Cat D)
No
Circuit integrity according to IEC 60331-23
No
Min. permitted bending radius, moving application with forced guidance
0mm
Specification material outer sheath
Other
Euro class flaming droplets/particles according to EN 13501-6
None
Reaction-to-fire class according to EN 13501-6
None
Min. permitted bending radius, moving application/free movement
0mm
Min. permitted bending radius, stationary application/permanent installation
64mm
Outer diameter approx.
11mm
Oil resistant (according to EN 60811-404)
Yes
Specification core insulation
Other
Permitted cable outer temperature during assembling/handling
-25 - 70°C
Permitted cable outer temperature after assembling without vibration
-25 - 70°C
Category
Other
NVP value
66.5%
UV resistant
Yes
Certified for shipboard application
No
Suitable as telephone cable
No
Suitable as computer data cable
No
Suitable for use as security alarm cable
No
Suitable as signalling cable
Yes
Drain wire
No
With rip cord
No
Cable width approx.
5.6mm
Cable height approx.
51.282mm
Nominal voltage U
24V
Characteristic impedance
100Ohm
Compatible with Grade3TV according to XP-C 90-483
No
With rodent protection
No
Compatible with Grade2TV according to XP-C 90-483
No
From same serie
SWD4-3LR4P-2S

Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Conductor surface
Bare
AWG size
20
Conductor category
Class 2 = stranded
Conductor material
Other
Core identification according to HD 308 S2
Cable type
Other
Material core insulation
Other
Screen over stranding element
Foil
Diameter conductor
1.5mm
Longitudinal water blocking cable
Radial water blocking cable
Approved type of underground installation
Other
Stranding
Bundle
Screen over stranding
None
Number of stranding elements
26
Stranding element
Pairs
Suitable for underground installation
Material outer sheath
Polyvinyl chloride (PVC)
Protective sheath
Other
Cable geometry
Round
Colour outer sheath
Black
Armouring/reinforcement
None
Flame retardant according to IEC 60332-3-24 (Cat C)
Number of cores
4
Flame retardant according to IEC 60332-3-23 (Cat B)
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
Material reinforcement
Other
Duplex
Nominal cross section conductor
0.5mm²
Flame retardant according to IEC 60332-1-2
Halogen free according to IEC 60754-1
Low smoke (according to IEC 61034-2)
Halogen free (according to IEC 60754-2)
Core identification
Colour
Euro class acidity according to EN 13501-6
None
Halogen free according to IEC 60754-3
Number of sheath layers
0
Smoke development class according to EN 13501-6
None
Flame retardant according to IEC 60332-3-22 (Cat A)
Flame retardant according to IEC 60332-3-25 (Cat D)
Circuit integrity according to IEC 60331-23
Min. permitted bending radius, moving application with forced guidance
0mm
Specification material outer sheath
Other
Euro class flaming droplets/particles according to EN 13501-6
None
Reaction-to-fire class according to EN 13501-6
None
Min. permitted bending radius, moving application/free movement
0mm
Min. permitted bending radius, stationary application/permanent installation
64mm
Outer diameter approx.
11mm
Oil resistant (according to EN 60811-404)
Specification core insulation
Other
Permitted cable outer temperature during assembling/handling
-25 .. 70°C
Permitted cable outer temperature after assembling without vibration
-25 .. 70°C
Category
Other
NVP value
66.5%
UV resistant
Certified for shipboard application
Suitable as telephone cable
Suitable as computer data cable
Suitable for use as security alarm cable
Suitable as signalling cable
Drain wire
With rip cord
Cable width approx.
5.6mm
Cable height approx.
51.282mm
Nominal voltage U
24V
Characteristic impedance
100Ohm
Compatible with Grade3TV according to XP-C 90-483
With rodent protection
Compatible with Grade2TV according to XP-C 90-483
From same serie