Aleta.hr
Main Product Image

SWD4-4LR4P-S

Code: 1747540

ManufacturerRAZNO
Catalog number183204
Type
EAN code4015081781379

Details

  • Cables
  • Data and communication cable
  • 1 KOM
  • EATON

Technical specifications

Duplex

No

Cable type

Other

Conductor material

Other

Diameter conductor

1.5mm

Conductor surface

Bare

AWG size

20

Nominal cross section conductor

0.5mm²

Number of stranding elements

26

Number of cores

4

Stranding element

Pairs

Specification core insulation

Other

Material core insulation

Other

Core identification according to HD 308 S2

No

Conductor category

Class 2 = stranded

Core identification

Colour

Screen over stranding element

Foil

Approved type of underground installation

Other

Stranding

Bundle

Radial water blocking cable

Yes

Screen over stranding

None

Protective sheath

Other

Suitable for underground installation

No

Material outer sheath

Polyvinyl chloride (PVC)

Armouring/reinforcement

None

Colour outer sheath

Black

Longitudinal water blocking cable

No

Specification material outer sheath

Other

Flame retardant according to IEC 60332-1-2

No

Flame retardant according to IEC 60332-3-21 (Cat A F/R)

No

Material reinforcement

Other

Flame retardant according to IEC 60332-3-23 (Cat B)

No

Cable geometry

Round

Number of sheath layers

0

Flame retardant according to IEC 60332-3-22 (Cat A)

No

Flame retardant according to IEC 60332-3-24 (Cat C)

No

Flame retardant according to IEC 60332-3-25 (Cat D)

No

Low smoke (according to IEC 61034-2)

No

Permitted cable outer temperature during assembling/handling

-25 - 70°C

Permitted cable outer temperature after assembling without vibration

-25 - 70°C

Category

Other

NVP value

66.5%

UV resistant

Yes

Certified for shipboard application

No

Suitable as computer data cable

No

Suitable as signalling cable

Yes

Suitable as telephone cable

No

Suitable for use as security alarm cable

No

Drain wire

No

With rip cord

No

Cable width approx.

5.6mm

Cable height approx.

51.282mm

Characteristic impedance

100Ohm

Nominal voltage U

24V

With rodent protection

No

Compatible with Grade2TV according to XP-C 90-483

No

Compatible with Grade3TV according to XP-C 90-483

No

Halogen free according to IEC 60754-1

No

Halogen free (according to IEC 60754-2)

No

Halogen free according to IEC 60754-3

No

Reaction-to-fire class according to EN 13501-6

None

Smoke development class according to EN 13501-6

None

Euro class flaming droplets/particles according to EN 13501-6

None

Euro class acidity according to EN 13501-6

None

Circuit integrity according to IEC 60331-23

No

Oil resistant (according to EN 60811-404)

Yes

Min. permitted bending radius, moving application/free movement

0mm

Min. permitted bending radius, stationary application/permanent installation

64mm

Min. permitted bending radius, moving application with forced guidance

0mm

Outer diameter approx.

11mm

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

SWD4-4LR4P-S

Main Product Image

Details

  • Cables
  • Data and communication cable
  • 1 KOM
  • EATON

Technical specifications

Duplex

Cable type

Other

Conductor material

Other

Diameter conductor

1.5mm

Conductor surface

Bare

AWG size

20

Nominal cross section conductor

0.5mm²

Number of stranding elements

26

Number of cores

4

Stranding element

Pairs

Specification core insulation

Other

Material core insulation

Other

Core identification according to HD 308 S2

Conductor category

Class 2 = stranded

Core identification

Colour

Screen over stranding element

Foil

Approved type of underground installation

Other

Stranding

Bundle

Radial water blocking cable

Screen over stranding

None

Protective sheath

Other

Suitable for underground installation

Material outer sheath

Polyvinyl chloride (PVC)

Armouring/reinforcement

None

Colour outer sheath

Black

Longitudinal water blocking cable

Specification material outer sheath

Other

Flame retardant according to IEC 60332-1-2

Flame retardant according to IEC 60332-3-21 (Cat A F/R)

Material reinforcement

Other

Flame retardant according to IEC 60332-3-23 (Cat B)

Cable geometry

Round

Number of sheath layers

0

Flame retardant according to IEC 60332-3-22 (Cat A)

Flame retardant according to IEC 60332-3-24 (Cat C)

Flame retardant according to IEC 60332-3-25 (Cat D)

Low smoke (according to IEC 61034-2)

Permitted cable outer temperature during assembling/handling

-25 .. 70°C

Permitted cable outer temperature after assembling without vibration

-25 .. 70°C

Category

Other

NVP value

66.5%

UV resistant

Certified for shipboard application

Suitable as computer data cable

Suitable as signalling cable

Suitable as telephone cable

Suitable for use as security alarm cable

Drain wire

With rip cord

Cable width approx.

5.6mm

Cable height approx.

51.282mm

Characteristic impedance

100Ohm

Nominal voltage U

24V

With rodent protection

Compatible with Grade2TV according to XP-C 90-483

Compatible with Grade3TV according to XP-C 90-483

Halogen free according to IEC 60754-1

Halogen free (according to IEC 60754-2)

Halogen free according to IEC 60754-3

Reaction-to-fire class according to EN 13501-6

None

Smoke development class according to EN 13501-6

None

Euro class flaming droplets/particles according to EN 13501-6

None

Euro class acidity according to EN 13501-6

None

Circuit integrity according to IEC 60331-23

Oil resistant (according to EN 60811-404)

Min. permitted bending radius, moving application/free movement

0mm

Min. permitted bending radius, stationary application/permanent installation

64mm

Min. permitted bending radius, moving application with forced guidance

0mm

Outer diameter approx.

11mm