Technical specifications

Nominal cross section conductor0.5mm²
Conductor materialOther
Material core insulationOther
AWG size20
Number of stranding elements26
Conductor categoryClass 2 = stranded
Specification core insulationOther
Diameter conductor1.5mm
Number of cores4
Stranding elementPairs
Conductor surfaceBare
DuplexNo
Radial water blocking cableYes
Approved type of underground installationOther
Protective sheathOther
Core identification according to HD 308 S2No
Specification material outer sheathOther
Armouring/reinforcementNone
Number of sheath layers0
Suitable for underground installationNo
Material reinforcementOther
Core identificationColour
Flame retardant according to IEC 60332-1-2No
Material outer sheathPolyvinyl chloride (PVC)
Flame retardant according to IEC 60332-3-21 (Cat A F/R)No
Colour outer sheathBlack
Screen over stranding elementFoil
Screen over strandingNone
StrandingBundle
Cable typeOther
Flame retardant according to IEC 60332-3-22 (Cat A)No
Longitudinal water blocking cableYes
Cable geometryRound
Halogen free according to IEC 60754-1No
Low smoke (according to IEC 61034-2)No
Flame retardant according to IEC 60332-3-24 (Cat C)No
Flame retardant according to IEC 60332-3-25 (Cat D)No
Halogen free (according to IEC 60754-2)No
Reaction-to-fire class according to EN 13501-6None
Halogen free according to IEC 60754-3No
Flame retardant according to IEC 60332-3-23 (Cat B)No
Permitted cable outer temperature during assembling/handling-25 - 70°C
CategoryOther
UV resistantYes
Permitted cable outer temperature after assembling without vibration-25 - 70°C
NVP value66.5%
Certified for shipboard applicationNo
Suitable as telephone cableNo
Suitable as computer data cableNo
Suitable as signalling cableYes
Suitable for use as security alarm cableNo
Drain wireNo
With rip cordNo
Cable height approx.307.692mm
Characteristic impedance100Ohm
Nominal voltage U24V
Cable width approx.5.6mm
With rodent protectionNo
Compatible with Grade2TV according to XP-C 90-483No
Compatible with Grade3TV according to XP-C 90-483No
Euro class acidity according to EN 13501-6None
Min. permitted bending radius, moving application/free movement0mm
Min. permitted bending radius, moving application with forced guidance0mm
Smoke development class according to EN 13501-6None
Euro class flaming droplets/particles according to EN 13501-6None
Circuit integrity according to IEC 60331-23No
Outer diameter approx.11mm
Oil resistant (according to EN 60811-404)Yes
Min. permitted bending radius, stationary application/permanent installation64mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SWD4-50LR4P

Main Product Image

Details

  • Cables
  • Data and communication cable
  • 1 KOM
  • EATON

Technical specifications

Nominal cross section conductor

0.5mm²

Conductor material

Other

Material core insulation

Other

AWG size

20

Number of stranding elements

26

Conductor category

Class 2 = stranded

Specification core insulation

Other

Diameter conductor

1.5mm

Number of cores

4

Stranding element

Pairs

Conductor surface

Bare

Duplex

Radial water blocking cable

Approved type of underground installation

Other

Protective sheath

Other

Core identification according to HD 308 S2

Specification material outer sheath

Other

Armouring/reinforcement

None

Number of sheath layers

0

Suitable for underground installation

Material reinforcement

Other

Core identification

Colour

Flame retardant according to IEC 60332-1-2

Material outer sheath

Polyvinyl chloride (PVC)

Flame retardant according to IEC 60332-3-21 (Cat A F/R)

Colour outer sheath

Black

Screen over stranding element

Foil

Screen over stranding

None

Stranding

Bundle

Cable type

Other

Flame retardant according to IEC 60332-3-22 (Cat A)

Longitudinal water blocking cable

Cable geometry

Round

Halogen free according to IEC 60754-1

Low smoke (according to IEC 61034-2)

Flame retardant according to IEC 60332-3-24 (Cat C)

Flame retardant according to IEC 60332-3-25 (Cat D)

Halogen free (according to IEC 60754-2)

Reaction-to-fire class according to EN 13501-6

None

Halogen free according to IEC 60754-3

Flame retardant according to IEC 60332-3-23 (Cat B)

Permitted cable outer temperature during assembling/handling

-25 .. 70°C

Category

Other

UV resistant

Permitted cable outer temperature after assembling without vibration

-25 .. 70°C

NVP value

66.5%

Certified for shipboard application

Suitable as telephone cable

Suitable as computer data cable

Suitable as signalling cable

Suitable for use as security alarm cable

Drain wire

With rip cord

Cable height approx.

307.692mm

Characteristic impedance

100Ohm

Nominal voltage U

24V

Cable width approx.

5.6mm

With rodent protection

Compatible with Grade2TV according to XP-C 90-483

Compatible with Grade3TV according to XP-C 90-483

Euro class acidity according to EN 13501-6

None

Min. permitted bending radius, moving application/free movement

0mm

Min. permitted bending radius, moving application with forced guidance

0mm

Smoke development class according to EN 13501-6

None

Euro class flaming droplets/particles according to EN 13501-6

None

Circuit integrity according to IEC 60331-23

Outer diameter approx.

11mm

Oil resistant (according to EN 60811-404)

Min. permitted bending radius, stationary application/permanent installation

64mm