Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Nominal cross section conductor
0.5mm²
Conductor material
Other
Material core insulation
Other
AWG size
20
Number of stranding elements
26
Conductor category
Class 2 = stranded
Specification core insulation
Other
Diameter conductor
1.5mm
Number of cores
4
Stranding element
Pairs
Conductor surface
Bare
Duplex
No
Radial water blocking cable
Yes
Approved type of underground installation
Other
Protective sheath
Other
Core identification according to HD 308 S2
No
Specification material outer sheath
Other
Armouring/reinforcement
None
Number of sheath layers
0
Suitable for underground installation
No
Material reinforcement
Other
Core identification
Colour
Flame retardant according to IEC 60332-1-2
No
Material outer sheath
Polyvinyl chloride (PVC)
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
No
Colour outer sheath
Black
Screen over stranding element
Foil
Screen over stranding
None
Stranding
Bundle
Cable type
Other
Flame retardant according to IEC 60332-3-22 (Cat A)
No
Longitudinal water blocking cable
Yes
Cable geometry
Round
Halogen free according to IEC 60754-1
No
Low smoke (according to IEC 61034-2)
No
Flame retardant according to IEC 60332-3-24 (Cat C)
No
Flame retardant according to IEC 60332-3-25 (Cat D)
No
Halogen free (according to IEC 60754-2)
No
Reaction-to-fire class according to EN 13501-6
None
Halogen free according to IEC 60754-3
No
Flame retardant according to IEC 60332-3-23 (Cat B)
No
Permitted cable outer temperature during assembling/handling
-25 - 70°C
Category
Other
UV resistant
Yes
Permitted cable outer temperature after assembling without vibration
-25 - 70°C
NVP value
66.5%
Certified for shipboard application
No
Suitable as telephone cable
No
Suitable as computer data cable
No
Suitable as signalling cable
Yes
Suitable for use as security alarm cable
No
Drain wire
No
With rip cord
No
Cable height approx.
307.692mm
Characteristic impedance
100Ohm
Nominal voltage U
24V
Cable width approx.
5.6mm
With rodent protection
No
Compatible with Grade2TV according to XP-C 90-483
No
Compatible with Grade3TV according to XP-C 90-483
No
Euro class acidity according to EN 13501-6
None
Min. permitted bending radius, moving application/free movement
0mm
Min. permitted bending radius, moving application with forced guidance
0mm
Smoke development class according to EN 13501-6
None
Euro class flaming droplets/particles according to EN 13501-6
None
Circuit integrity according to IEC 60331-23
No
Outer diameter approx.
11mm
Oil resistant (according to EN 60811-404)
Yes
Min. permitted bending radius, stationary application/permanent installation
64mm
From same serie
SWD4-50LR4P

Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Nominal cross section conductor
0.5mm²
Conductor material
Other
Material core insulation
Other
AWG size
20
Number of stranding elements
26
Conductor category
Class 2 = stranded
Specification core insulation
Other
Diameter conductor
1.5mm
Number of cores
4
Stranding element
Pairs
Conductor surface
Bare
Duplex
Radial water blocking cable
Approved type of underground installation
Other
Protective sheath
Other
Core identification according to HD 308 S2
Specification material outer sheath
Other
Armouring/reinforcement
None
Number of sheath layers
0
Suitable for underground installation
Material reinforcement
Other
Core identification
Colour
Flame retardant according to IEC 60332-1-2
Material outer sheath
Polyvinyl chloride (PVC)
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
Colour outer sheath
Black
Screen over stranding element
Foil
Screen over stranding
None
Stranding
Bundle
Cable type
Other
Flame retardant according to IEC 60332-3-22 (Cat A)
Longitudinal water blocking cable
Cable geometry
Round
Halogen free according to IEC 60754-1
Low smoke (according to IEC 61034-2)
Flame retardant according to IEC 60332-3-24 (Cat C)
Flame retardant according to IEC 60332-3-25 (Cat D)
Halogen free (according to IEC 60754-2)
Reaction-to-fire class according to EN 13501-6
None
Halogen free according to IEC 60754-3
Flame retardant according to IEC 60332-3-23 (Cat B)
Permitted cable outer temperature during assembling/handling
-25 .. 70°C
Category
Other
UV resistant
Permitted cable outer temperature after assembling without vibration
-25 .. 70°C
NVP value
66.5%
Certified for shipboard application
Suitable as telephone cable
Suitable as computer data cable
Suitable as signalling cable
Suitable for use as security alarm cable
Drain wire
With rip cord
Cable height approx.
307.692mm
Characteristic impedance
100Ohm
Nominal voltage U
24V
Cable width approx.
5.6mm
With rodent protection
Compatible with Grade2TV according to XP-C 90-483
Compatible with Grade3TV according to XP-C 90-483
Euro class acidity according to EN 13501-6
None
Min. permitted bending radius, moving application/free movement
0mm
Min. permitted bending radius, moving application with forced guidance
0mm
Smoke development class according to EN 13501-6
None
Euro class flaming droplets/particles according to EN 13501-6
None
Circuit integrity according to IEC 60331-23
Outer diameter approx.
11mm
Oil resistant (according to EN 60811-404)
Min. permitted bending radius, stationary application/permanent installation
64mm
From same serie