Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Diameter conductor
1.5mm
Duplex
No
Conductor surface
Bare
Cable type
Other
Conductor material
Other
Conductor category
Class 2 = stranded
Stranding element
Pairs
Specification core insulation
Other
Core identification according to HD 308 S2
No
Core identification
Colour
Screen over stranding
None
Suitable for underground installation
No
Radial water blocking cable
Yes
Material core insulation
Other
Stranding
Bundle
Number of stranding elements
26
Protective sheath
Other
Nominal cross section conductor
0.5mm²
Longitudinal water blocking cable
No
Number of cores
4
Approved type of underground installation
Other
Specification material outer sheath
Other
Material outer sheath
Polyvinyl chloride (PVC)
Colour outer sheath
Black
Number of sheath layers
0
Material reinforcement
Other
Screen over stranding element
Foil
AWG size
20
Armouring/reinforcement
None
Cable geometry
Round
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
No
Flame retardant according to IEC 60332-1-2
No
Flame retardant according to IEC 60332-3-22 (Cat A)
No
Flame retardant according to IEC 60332-3-25 (Cat D)
No
Low smoke (according to IEC 61034-2)
No
Halogen free according to IEC 60754-1
No
Flame retardant according to IEC 60332-3-23 (Cat B)
No
Reaction-to-fire class according to EN 13501-6
None
Halogen free (according to IEC 60754-2)
No
Halogen free according to IEC 60754-3
No
Euro class acidity according to EN 13501-6
None
Smoke development class according to EN 13501-6
None
Permitted cable outer temperature during assembling/handling
-25 - 70°C
Euro class flaming droplets/particles according to EN 13501-6
None
Flame retardant according to IEC 60332-3-24 (Cat C)
No
Category
Other
Permitted cable outer temperature after assembling without vibration
-25 - 70°C
NVP value
66.5%
UV resistant
No
Certified for shipboard application
No
Suitable as computer data cable
No
Suitable as telephone cable
No
Suitable as signalling cable
Yes
Suitable for use as security alarm cable
No
Drain wire
No
With rip cord
No
Cable width approx.
5.6mm
Characteristic impedance
100Ohm
Nominal voltage U
24V
Cable height approx.
51.282mm
With rodent protection
No
Compatible with Grade2TV according to XP-C 90-483
No
Compatible with Grade3TV according to XP-C 90-483
No
Min. permitted bending radius, moving application with forced guidance
0mm
Outer diameter approx.
11mm
Circuit integrity according to IEC 60331-23
No
Min. permitted bending radius, moving application/free movement
0mm
Oil resistant (according to EN 60811-404)
Yes
Min. permitted bending radius, stationary application/permanent installation
64mm
SWD4-5LR4P-2R

Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Diameter conductor
1.5mm
Duplex
Conductor surface
Bare
Cable type
Other
Conductor material
Other
Conductor category
Class 2 = stranded
Stranding element
Pairs
Specification core insulation
Other
Core identification according to HD 308 S2
Core identification
Colour
Screen over stranding
None
Suitable for underground installation
Radial water blocking cable
Material core insulation
Other
Stranding
Bundle
Number of stranding elements
26
Protective sheath
Other
Nominal cross section conductor
0.5mm²
Longitudinal water blocking cable
Number of cores
4
Approved type of underground installation
Other
Specification material outer sheath
Other
Material outer sheath
Polyvinyl chloride (PVC)
Colour outer sheath
Black
Number of sheath layers
0
Material reinforcement
Other
Screen over stranding element
Foil
AWG size
20
Armouring/reinforcement
None
Cable geometry
Round
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
Flame retardant according to IEC 60332-1-2
Flame retardant according to IEC 60332-3-22 (Cat A)
Flame retardant according to IEC 60332-3-25 (Cat D)
Low smoke (according to IEC 61034-2)
Halogen free according to IEC 60754-1
Flame retardant according to IEC 60332-3-23 (Cat B)
Reaction-to-fire class according to EN 13501-6
None
Halogen free (according to IEC 60754-2)
Halogen free according to IEC 60754-3
Euro class acidity according to EN 13501-6
None
Smoke development class according to EN 13501-6
None
Permitted cable outer temperature during assembling/handling
-25 .. 70°C
Euro class flaming droplets/particles according to EN 13501-6
None
Flame retardant according to IEC 60332-3-24 (Cat C)
Category
Other
Permitted cable outer temperature after assembling without vibration
-25 .. 70°C
NVP value
66.5%
UV resistant
Certified for shipboard application
Suitable as computer data cable
Suitable as telephone cable
Suitable as signalling cable
Suitable for use as security alarm cable
Drain wire
With rip cord
Cable width approx.
5.6mm
Characteristic impedance
100Ohm
Nominal voltage U
24V
Cable height approx.
51.282mm
With rodent protection
Compatible with Grade2TV according to XP-C 90-483
Compatible with Grade3TV according to XP-C 90-483
Min. permitted bending radius, moving application with forced guidance
0mm
Outer diameter approx.
11mm
Circuit integrity according to IEC 60331-23
Min. permitted bending radius, moving application/free movement
0mm
Oil resistant (according to EN 60811-404)
Min. permitted bending radius, stationary application/permanent installation
64mm
We use cookies to enhance your experience.