Technical specifications

UV resistantYes
Nominal cross section conductor0.5mm²
Cable typeOther
Material core insulationOther
Drain wireNo
Nominal voltage U24V
Core identificationColour
Conductor materialOther
Material outer sheathPolyvinyl chloride (PVC)
Diameter conductor1.5mm
Screen over strandingNone
Screen over stranding elementFoil
Stranding elementPairs
Conductor categoryClass 2 = stranded
Characteristic impedance100Ohm
Colour outer sheathBlack
CategoryOther
Permitted cable outer temperature after assembling without vibration-25 - 70°C
Halogen free (according to IEC 60754-2)No
Protective sheathOther
Permitted cable outer temperature during assembling/handling-25 - 70°C
Number of cores4
Number of stranding elements26
Cable width approx.5.6mm
Suitable for underground installationNo
With rodent protectionNo
StrandingBundle
Outer diameter approx.11mm
Cable height approx.51.282mm
Low smoke (according to IEC 61034-2)No
Armouring/reinforcementNone
NVP value66.5%
Reaction-to-fire class according to EN 13501-6None
Smoke development class according to EN 13501-6None
Conductor surfaceBare
Longitudinal water blocking cableNo
AWG size20
Euro class acidity according to EN 13501-6None
Radial water blocking cableYes
Oil resistant (according to EN 60811-404)Yes
Min. permitted bending radius, stationary application/permanent installation64mm
Specification material outer sheathPolypropylene (PP)
Material reinforcementOther
Specification core insulationOther
Suitable as computer data cableNo
Min. permitted bending radius, moving application/free movement0mm
Core identification according to HD 308 S2No
Min. permitted bending radius, moving application with forced guidance0mm
Cable geometryRound
Suitable as telephone cableNo
Euro class flaming droplets/particles according to EN 13501-6None
Certified for shipboard applicationNo
Flame retardant according to IEC 60332-3-22 (Cat A)No
Approved type of underground installationOther
Flame retardant according to IEC 60332-3-21 (Cat A F/R)No
Suitable as signalling cableYes
Flame retardant according to IEC 60332-1-2No
Halogen free according to IEC 60754-3No
Number of sheath layers0
Flame retardant according to IEC 60332-3-25 (Cat D)No
Suitable for use as security alarm cableNo
Flame retardant according to IEC 60332-3-24 (Cat C)No
Circuit integrity according to IEC 60331-23No
Halogen free according to IEC 60754-1No
Flame retardant according to IEC 60332-3-23 (Cat B)No
With rip cordNo
Compatible with Grade2TV according to XP-C 90-483No
DuplexNo
Compatible with Grade3TV according to XP-C 90-483No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SWD4-6LR4P-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Cables
  • Data and communication cable
  • 1 KOM
  • EATON

Technical specifications

UV resistant

Nominal cross section conductor

0.5mm²

Cable type

Other

Material core insulation

Other

Drain wire

Nominal voltage U

24V

Core identification

Colour

Conductor material

Other

Material outer sheath

Polyvinyl chloride (PVC)

Diameter conductor

1.5mm

Screen over stranding

None

Screen over stranding element

Foil

Stranding element

Pairs

Conductor category

Class 2 = stranded

Characteristic impedance

100Ohm

Colour outer sheath

Black

Category

Other

Permitted cable outer temperature after assembling without vibration

-25 .. 70°C

Halogen free (according to IEC 60754-2)

Protective sheath

Other

Permitted cable outer temperature during assembling/handling

-25 .. 70°C

Number of cores

4

Number of stranding elements

26

Cable width approx.

5.6mm

Suitable for underground installation

With rodent protection

Stranding

Bundle

Outer diameter approx.

11mm

Cable height approx.

51.282mm

Low smoke (according to IEC 61034-2)

Armouring/reinforcement

None

NVP value

66.5%

Reaction-to-fire class according to EN 13501-6

None

Smoke development class according to EN 13501-6

None

Conductor surface

Bare

Longitudinal water blocking cable

AWG size

20

Euro class acidity according to EN 13501-6

None

Radial water blocking cable

Oil resistant (according to EN 60811-404)

Min. permitted bending radius, stationary application/permanent installation

64mm

Specification material outer sheath

Polypropylene (PP)

Material reinforcement

Other

Specification core insulation

Other

Suitable as computer data cable

Min. permitted bending radius, moving application/free movement

0mm

Core identification according to HD 308 S2

Min. permitted bending radius, moving application with forced guidance

0mm

Cable geometry

Round

Suitable as telephone cable

Euro class flaming droplets/particles according to EN 13501-6

None

Certified for shipboard application

Flame retardant according to IEC 60332-3-22 (Cat A)

Approved type of underground installation

Other

Flame retardant according to IEC 60332-3-21 (Cat A F/R)

Suitable as signalling cable

Flame retardant according to IEC 60332-1-2

Halogen free according to IEC 60754-3

Number of sheath layers

0

Flame retardant according to IEC 60332-3-25 (Cat D)

Suitable for use as security alarm cable

Flame retardant according to IEC 60332-3-24 (Cat C)

Circuit integrity according to IEC 60331-23

Halogen free according to IEC 60754-1

Flame retardant according to IEC 60332-3-23 (Cat B)

With rip cord

Compatible with Grade2TV according to XP-C 90-483

Duplex

Compatible with Grade3TV according to XP-C 90-483

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.