Aleta.hr
Main Product Image

SWD4-M3LR4P-2R

Code: 1747546

ManufacturerEaton (Moeller)
Catalog number183218
TypeCables
EAN code4015081781515

















Details

  • Cables
  • Data and communication cable
  • 1 KOM
  • EATON

Technical specifications

AWG size20
Conductor surfaceBare
Conductor categoryClass 2 = stranded
Cable typeOther
Screen over stranding elementFoil
Core identification according to HD 308 S2No
Specification core insulationOther
Number of stranding elements26
Conductor materialOther
Core identificationColour
Stranding elementPairs
Material core insulationOther
Nominal cross section conductor0.5mm²
Number of cores4
Protective sheathOther
Material outer sheathPolyvinyl chloride (PVC)
Screen over strandingNone
Approved type of underground installationOther
Suitable for underground installationNo
Colour outer sheathBlack
Specification material outer sheathOther
Cable geometryRound
Flame retardant according to IEC 60332-1-2No
Material reinforcementOther
Flame retardant according to IEC 60332-3-22 (Cat A)No
Longitudinal water blocking cableNo
Flame retardant according to IEC 60332-3-21 (Cat A F/R)No
Armouring/reinforcementNone
Flame retardant according to IEC 60332-3-24 (Cat C)No
Diameter conductor1.5mm
Halogen free according to IEC 60754-3No
Flame retardant according to IEC 60332-3-25 (Cat D)No
Flame retardant according to IEC 60332-3-23 (Cat B)No
Number of sheath layers0
Reaction-to-fire class according to EN 13501-6None
Min. permitted bending radius, moving application/free movement0mm
Halogen free according to IEC 60754-1No
Low smoke (according to IEC 61034-2)No
Circuit integrity according to IEC 60331-23No
Euro class flaming droplets/particles according to EN 13501-6None
Min. permitted bending radius, stationary application/permanent installation64mm
DuplexNo
Euro class acidity according to EN 13501-6None
Halogen free (according to IEC 60754-2)No
Min. permitted bending radius, moving application with forced guidance0mm
Outer diameter approx.11mm
Oil resistant (according to EN 60811-404)Yes
Radial water blocking cableYes
StrandingBundle
Smoke development class according to EN 13501-6None
Permitted cable outer temperature during assembling/handling-25 - 70°C
Permitted cable outer temperature after assembling without vibration-25 - 70°C
CategoryOther
NVP value66.5%
UV resistantNo
Certified for shipboard applicationNo
Suitable as telephone cableNo
Suitable as computer data cableNo
Suitable as signalling cableYes
Suitable for use as security alarm cableNo
With rip cordNo
Drain wireNo
Cable width approx.5.6mm
Cable height approx.51.282mm
Characteristic impedance100Ohm
Nominal voltage U24V
With rodent protectionNo
Compatible with Grade2TV according to XP-C 90-483No
Compatible with Grade3TV according to XP-C 90-483No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SWD4-M3LR4P-2R

Main Product Image

Details

  • Cables
  • Data and communication cable
  • 1 KOM
  • EATON

Technical specifications

AWG size

20

Conductor surface

Bare

Conductor category

Class 2 = stranded

Cable type

Other

Screen over stranding element

Foil

Core identification according to HD 308 S2

Specification core insulation

Other

Number of stranding elements

26

Conductor material

Other

Core identification

Colour

Stranding element

Pairs

Material core insulation

Other

Nominal cross section conductor

0.5mm²

Number of cores

4

Protective sheath

Other

Material outer sheath

Polyvinyl chloride (PVC)

Screen over stranding

None

Approved type of underground installation

Other

Suitable for underground installation

Colour outer sheath

Black

Specification material outer sheath

Other

Cable geometry

Round

Flame retardant according to IEC 60332-1-2

Material reinforcement

Other

Flame retardant according to IEC 60332-3-22 (Cat A)

Longitudinal water blocking cable

Flame retardant according to IEC 60332-3-21 (Cat A F/R)

Armouring/reinforcement

None

Flame retardant according to IEC 60332-3-24 (Cat C)

Diameter conductor

1.5mm

Halogen free according to IEC 60754-3

Flame retardant according to IEC 60332-3-25 (Cat D)

Flame retardant according to IEC 60332-3-23 (Cat B)

Number of sheath layers

0

Reaction-to-fire class according to EN 13501-6

None

Min. permitted bending radius, moving application/free movement

0mm

Halogen free according to IEC 60754-1

Low smoke (according to IEC 61034-2)

Circuit integrity according to IEC 60331-23

Euro class flaming droplets/particles according to EN 13501-6

None

Min. permitted bending radius, stationary application/permanent installation

64mm

Duplex

Euro class acidity according to EN 13501-6

None

Halogen free (according to IEC 60754-2)

Min. permitted bending radius, moving application with forced guidance

0mm

Outer diameter approx.

11mm

Oil resistant (according to EN 60811-404)

Radial water blocking cable

Stranding

Bundle

Smoke development class according to EN 13501-6

None

Permitted cable outer temperature during assembling/handling

-25 .. 70°C

Permitted cable outer temperature after assembling without vibration

-25 .. 70°C

Category

Other

NVP value

66.5%

UV resistant

Certified for shipboard application

Suitable as telephone cable

Suitable as computer data cable

Suitable as signalling cable

Suitable for use as security alarm cable

With rip cord

Drain wire

Cable width approx.

5.6mm

Cable height approx.

51.282mm

Characteristic impedance

100Ohm

Nominal voltage U

24V

With rodent protection

Compatible with Grade2TV according to XP-C 90-483

Compatible with Grade3TV according to XP-C 90-483

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.