Aleta.hr
Main Product Image

SWD4-M3LR4P-2S

Code: 1747547

ManufacturerEaton (Moeller)
Catalog number183208
TypeCables
EAN code4015081781416

















Details

  • Cables
  • Data and communication cable
  • 1 KOM
  • EATON

Technical specifications

Conductor materialOther
Cable typeOther
DuplexNo
Diameter conductor1.5mm
Conductor surfaceBare
Number of cores4
AWG size20
Nominal cross section conductor0.5mm²
Number of stranding elements26
Material core insulationOther
Specification core insulationOther
Core identification according to HD 308 S2No
Conductor categoryClass 2 = stranded
Screen over stranding elementFoil
StrandingBundle
Stranding elementPairs
Radial water blocking cableYes
Screen over strandingNone
Core identificationColour
Approved type of underground installationOther
Protective sheathOther
Suitable for underground installationNo
Armouring/reinforcementNone
Material outer sheathPolyvinyl chloride (PVC)
Specification material outer sheathOther
Colour outer sheathBlack
Material reinforcementOther
Cable geometryRound
Flame retardant according to IEC 60332-1-2No
Flame retardant according to IEC 60332-3-24 (Cat C)No
Number of sheath layers0
Flame retardant according to IEC 60332-3-21 (Cat A F/R)No
Flame retardant according to IEC 60332-3-23 (Cat B)No
Low smoke (according to IEC 61034-2)No
Halogen free according to IEC 60754-1No
Flame retardant according to IEC 60332-3-22 (Cat A)No
Flame retardant according to IEC 60332-3-25 (Cat D)No
Reaction-to-fire class according to EN 13501-6None
Euro class acidity according to EN 13501-6None
Circuit integrity according to IEC 60331-23No
Longitudinal water blocking cableYes
Oil resistant (according to EN 60811-404)Yes
Euro class flaming droplets/particles according to EN 13501-6None
Halogen free according to IEC 60754-3No
Outer diameter approx.11mm
Halogen free (according to IEC 60754-2)No
Min. permitted bending radius, moving application with forced guidance0mm
Min. permitted bending radius, stationary application/permanent installation64mm
Min. permitted bending radius, moving application/free movement0mm
Smoke development class according to EN 13501-6None
Permitted cable outer temperature during assembling/handling-25 - 70°C
Permitted cable outer temperature after assembling without vibration-25 - 70°C
CategoryOther
NVP value66.5%
UV resistantNo
Certified for shipboard applicationNo
Suitable as computer data cableNo
Suitable as signalling cableYes
Suitable as telephone cableNo
Suitable for use as security alarm cableNo
Drain wireNo
With rip cordNo
Cable width approx.5.6mm
Characteristic impedance100Ohm
Cable height approx.51.282mm
Nominal voltage U24V
With rodent protectionNo
Compatible with Grade2TV according to XP-C 90-483No
Compatible with Grade3TV according to XP-C 90-483No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SWD4-M3LR4P-2S

Main Product Image

Details

  • Cables
  • Data and communication cable
  • 1 KOM
  • EATON

Technical specifications

Conductor material

Other

Cable type

Other

Duplex

Diameter conductor

1.5mm

Conductor surface

Bare

Number of cores

4

AWG size

20

Nominal cross section conductor

0.5mm²

Number of stranding elements

26

Material core insulation

Other

Specification core insulation

Other

Core identification according to HD 308 S2

Conductor category

Class 2 = stranded

Screen over stranding element

Foil

Stranding

Bundle

Stranding element

Pairs

Radial water blocking cable

Screen over stranding

None

Core identification

Colour

Approved type of underground installation

Other

Protective sheath

Other

Suitable for underground installation

Armouring/reinforcement

None

Material outer sheath

Polyvinyl chloride (PVC)

Specification material outer sheath

Other

Colour outer sheath

Black

Material reinforcement

Other

Cable geometry

Round

Flame retardant according to IEC 60332-1-2

Flame retardant according to IEC 60332-3-24 (Cat C)

Number of sheath layers

0

Flame retardant according to IEC 60332-3-21 (Cat A F/R)

Flame retardant according to IEC 60332-3-23 (Cat B)

Low smoke (according to IEC 61034-2)

Halogen free according to IEC 60754-1

Flame retardant according to IEC 60332-3-22 (Cat A)

Flame retardant according to IEC 60332-3-25 (Cat D)

Reaction-to-fire class according to EN 13501-6

None

Euro class acidity according to EN 13501-6

None

Circuit integrity according to IEC 60331-23

Longitudinal water blocking cable

Oil resistant (according to EN 60811-404)

Euro class flaming droplets/particles according to EN 13501-6

None

Halogen free according to IEC 60754-3

Outer diameter approx.

11mm

Halogen free (according to IEC 60754-2)

Min. permitted bending radius, moving application with forced guidance

0mm

Min. permitted bending radius, stationary application/permanent installation

64mm

Min. permitted bending radius, moving application/free movement

0mm

Smoke development class according to EN 13501-6

None

Permitted cable outer temperature during assembling/handling

-25 .. 70°C

Permitted cable outer temperature after assembling without vibration

-25 .. 70°C

Category

Other

NVP value

66.5%

UV resistant

Certified for shipboard application

Suitable as computer data cable

Suitable as signalling cable

Suitable as telephone cable

Suitable for use as security alarm cable

Drain wire

With rip cord

Cable width approx.

5.6mm

Characteristic impedance

100Ohm

Cable height approx.

51.282mm

Nominal voltage U

24V

With rodent protection

Compatible with Grade2TV according to XP-C 90-483

Compatible with Grade3TV according to XP-C 90-483

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.