Aleta.hr
Main Product Image

SWD4-M3LR4P-2S

Code: 1747547

ManufacturerEaton (Moeller)
Catalog number183208
TypeCables
EAN code4015081781416

Details

  • Cables
  • Data and communication cable
  • 1 KOM
  • EATON

Technical specifications

Core identificationColour
Nominal voltage U24V
Drain wireNo
Screen over stranding elementFoil
Material core insulationOther
Permitted cable outer temperature during assembling/handling-25 - 70°C
UV resistantNo
CategoryOther
Cable typeOther
Conductor categoryClass 2 = stranded
Characteristic impedance100Ohm
Stranding elementPairs
Nominal cross section conductor0.5mm²
Screen over strandingNone
Material outer sheathPolyvinyl chloride (PVC)
Colour outer sheathBlack
Armouring/reinforcementNone
Conductor materialOther
Diameter conductor1.5mm
AWG size20
NVP value66.5%
With rodent protectionNo
StrandingBundle
Euro class flaming droplets/particles according to EN 13501-6None
Euro class acidity according to EN 13501-6None
Halogen free (according to IEC 60754-2)No
Suitable for underground installationNo
Radial water blocking cableYes
Number of stranding elements26
Conductor surfaceBare
Protective sheathOther
Permitted cable outer temperature after assembling without vibration-25 - 70°C
Number of cores4
Min. permitted bending radius, moving application/free movement0mm
Low smoke (according to IEC 61034-2)No
Reaction-to-fire class according to EN 13501-6None
Min. permitted bending radius, moving application with forced guidance0mm
Outer diameter approx.11mm
Smoke development class according to EN 13501-6None
Cable width approx.5.6mm
Oil resistant (according to EN 60811-404)Yes
Min. permitted bending radius, stationary application/permanent installation64mm
Cable height approx.51.282mm
Longitudinal water blocking cableYes
Approved type of underground installationOther
Certified for shipboard applicationNo
Suitable as computer data cableNo
Suitable as telephone cableNo
Cable geometryRound
Halogen free according to IEC 60754-1No
Suitable as signalling cableYes
Circuit integrity according to IEC 60331-23No
Flame retardant according to IEC 60332-3-25 (Cat D)No
With rip cordNo
Compatible with Grade3TV according to XP-C 90-483No
Suitable for use as security alarm cableNo
Specification core insulationOther
Number of sheath layers0
Halogen free according to IEC 60754-3No
Compatible with Grade2TV according to XP-C 90-483No
Specification material outer sheathOther
Flame retardant according to IEC 60332-3-21 (Cat A F/R)No
DuplexNo
Material reinforcementOther
Flame retardant according to IEC 60332-3-22 (Cat A)No
Flame retardant according to IEC 60332-3-23 (Cat B)No
Flame retardant according to IEC 60332-3-24 (Cat C)No
Flame retardant according to IEC 60332-1-2No
Core identification according to HD 308 S2No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SWD4-M3LR4P-2S

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Cables
  • Data and communication cable
  • 1 KOM
  • EATON

Technical specifications

Core identification

Colour

Nominal voltage U

24V

Drain wire

Screen over stranding element

Foil

Material core insulation

Other

Permitted cable outer temperature during assembling/handling

-25 .. 70°C

UV resistant

Category

Other

Cable type

Other

Conductor category

Class 2 = stranded

Characteristic impedance

100Ohm

Stranding element

Pairs

Nominal cross section conductor

0.5mm²

Screen over stranding

None

Material outer sheath

Polyvinyl chloride (PVC)

Colour outer sheath

Black

Armouring/reinforcement

None

Conductor material

Other

Diameter conductor

1.5mm

AWG size

20

NVP value

66.5%

With rodent protection

Stranding

Bundle

Euro class flaming droplets/particles according to EN 13501-6

None

Euro class acidity according to EN 13501-6

None

Halogen free (according to IEC 60754-2)

Suitable for underground installation

Radial water blocking cable

Number of stranding elements

26

Conductor surface

Bare

Protective sheath

Other

Permitted cable outer temperature after assembling without vibration

-25 .. 70°C

Number of cores

4

Min. permitted bending radius, moving application/free movement

0mm

Low smoke (according to IEC 61034-2)

Reaction-to-fire class according to EN 13501-6

None

Min. permitted bending radius, moving application with forced guidance

0mm

Outer diameter approx.

11mm

Smoke development class according to EN 13501-6

None

Cable width approx.

5.6mm

Oil resistant (according to EN 60811-404)

Min. permitted bending radius, stationary application/permanent installation

64mm

Cable height approx.

51.282mm

Longitudinal water blocking cable

Approved type of underground installation

Other

Certified for shipboard application

Suitable as computer data cable

Suitable as telephone cable

Cable geometry

Round

Halogen free according to IEC 60754-1

Suitable as signalling cable

Circuit integrity according to IEC 60331-23

Flame retardant according to IEC 60332-3-25 (Cat D)

With rip cord

Compatible with Grade3TV according to XP-C 90-483

Suitable for use as security alarm cable

Specification core insulation

Other

Number of sheath layers

0

Halogen free according to IEC 60754-3

Compatible with Grade2TV according to XP-C 90-483

Specification material outer sheath

Other

Flame retardant according to IEC 60332-3-21 (Cat A F/R)

Duplex

Material reinforcement

Other

Flame retardant according to IEC 60332-3-22 (Cat A)

Flame retardant according to IEC 60332-3-23 (Cat B)

Flame retardant according to IEC 60332-3-24 (Cat C)

Flame retardant according to IEC 60332-1-2

Core identification according to HD 308 S2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.