Details

  • •Supply cable for SWD modules IP67 EU6E, EU8E, 0
  • •Cables
  • •Data and communication cable
  • •Minimum order quantity: 1 pcs
  • •EATON

Technical specifications

Stranding elementPairs
Diameter conductor1.5mm
UV resistantNo
Material core insulationOther
CategoryOther
Nominal voltage U24V
Drain wireNo
Core identificationColour
Screen over stranding elementFoil
Smoke development class according to EN 13501-6None
Protective sheathOther
Low smoke (according to IEC 61034-2)No
Characteristic impedance100Ohm
Permitted cable outer temperature after assembling without vibration-25 - 70°C
Number of stranding elements26
Screen over strandingNone
Number of cores4
Cable width approx.5.6mm
Oil resistant (according to EN 60811-404)Yes
Halogen free (according to IEC 60754-2)No
Radial water blocking cableYes
NVP value66.5%
Suitable for underground installationNo
Conductor surfaceBare
With rodent protectionNo
Armouring/reinforcementNone
StrandingBundle
Longitudinal water blocking cableYes
Permitted cable outer temperature during assembling/handling-25 - 70°C
Cable height approx.51.282mm
Material outer sheathPolyvinyl chloride (PVC)
Reaction-to-fire class according to EN 13501-6None
Outer diameter approx.11mm
Conductor categoryClass 2 = stranded
Euro class flaming droplets/particles according to EN 13501-6None
Specification material outer sheathOther
Circuit integrity according to IEC 60331-23No
Min. permitted bending radius, moving application/free movement0mm
Flame retardant according to IEC 60332-3-21 (Cat A F/R)No
AWG size20
Approved type of underground installationOther
Cable geometryRound
Specification core insulationOther
Flame retardant according to IEC 60332-3-25 (Cat D)No
Material reinforcementOther
Flame retardant according to IEC 60332-3-23 (Cat B)No
Flame retardant according to IEC 60332-3-22 (Cat A)No
Suitable as telephone cableNo
Flame retardant according to IEC 60332-3-24 (Cat C)No
Suitable as signalling cableYes
Certified for shipboard applicationNo
Flame retardant according to IEC 60332-1-2No
Core identification according to HD 308 S2No
Suitable as computer data cableNo
Halogen free according to IEC 60754-1No
Min. permitted bending radius, stationary application/permanent installation64mm
Halogen free according to IEC 60754-3No
Euro class acidity according to EN 13501-6None
Min. permitted bending radius, moving application with forced guidance0mm
With rip cordNo
Number of sheath layers0
DuplexNo
Compatible with Grade2TV according to XP-C 90-483No
Suitable for use as security alarm cableNo
Compatible with Grade3TV according to XP-C 90-483No
Nominal cross section conductor0.5mm²
Cable typeOther
Colour outer sheathBlack
Conductor materialOther
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as