Aleta.hr

Details

  • Low-voltage industrial components
  • Contactor relay
  • 1 KOM
  • ABB

Technical specifications

Height86mm
Depth110.5mm
Width45mm
Mounting methodDIN-rail/screw
InterfaceNo
Number of auxiliary contacts as normally open contact6
Rated control supply voltage Us at AC 50HZ48 - 130V
With LED indicationNo
Number of auxiliary contacts as change-over contact0
Rated control supply voltage Us at AC 60HZ48 - 130V
Rated control supply voltage Us at DC48 - 130V
Rated operation current Ie, 400 V3A
Suitable for manual operationNo
Number of auxiliary contacts as normally closed contact2
Manual operation possibleNo
Rated switch current-A
Number of auxiliary contacts as normally closed contact, delayed switching0
Connection type auxiliary circuitScrew connection
Number of auxiliary contacts as normally open contact, leading0
Operating voltage at AC 60 Hz690 - 690V
Rated operation current3A
Operating voltage at AC 50 Hz690 - 690V
Voltage type for actuatingAC/DC
Operating voltage at DC6 - 6V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SBH137001R1259 | NF51/11-12 48-130V50/60HZ-DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Contactor relay
  • 1 KOM
  • ABB

Technical specifications

Height

86mm

Depth

110.5mm

Width

45mm

Mounting method

DIN-rail/screw

Interface

Number of auxiliary contacts as normally open contact

6

Rated control supply voltage Us at AC 50HZ

48 .. 130V

With LED indication

Number of auxiliary contacts as change-over contact

0

Rated control supply voltage Us at AC 60HZ

48 .. 130V

Rated control supply voltage Us at DC

48 .. 130V

Rated operation current Ie, 400 V

3A

Suitable for manual operation

Number of auxiliary contacts as normally closed contact

2

Manual operation possible

Rated switch current

-A

Number of auxiliary contacts as normally closed contact, delayed switching

0

Connection type auxiliary circuit

Screw connection

Number of auxiliary contacts as normally open contact, leading

0

Operating voltage at AC 60 Hz

690 .. 690V

Rated operation current

3A

Operating voltage at AC 50 Hz

690 .. 690V

Voltage type for actuating

AC/DC

Operating voltage at DC

6 .. 6V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.