  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeAC/DC
Explosion-proofNo
Release characteristicB
Rated insulation voltage Ui500V
Pollution degree3
Current limiting class3
Over voltage category3
Frequency50 - 60Hz
Width in number of modular spacings4
Rated current13A
Rated voltage440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Number of protected poles1
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 50mm²
Number of poles (total)1
Additional equipment possibleYes
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Flush-mounted installationNo
Power loss2W
Connectable conductor cross section multi-wired0 - 70mm²
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS881001R0135 | S801C-B13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

AC/DC

Explosion-proof

Release characteristic

B

Rated insulation voltage Ui

500V

Pollution degree

3

Current limiting class

3

Over voltage category

3

Frequency

50 .. 60Hz

Width in number of modular spacings

4

Rated current

13A

Rated voltage

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Number of protected poles

1

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 50mm²

Number of poles (total)

1

Additional equipment possible

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Flush-mounted installation

Power loss

2W

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated impulse withstand voltage Uimp

8kV