Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Frequency50 - 60Hz
Built-in depth82.5mm
Rated insulation voltage Ui500V
Current limiting class3
Release characteristicK
Rated current25A
Rated voltage440V
Pollution degree3
Power loss4.3W
Degree of protection (IP)IP20
Explosion-proofNo
Width in number of modular spacings4
Number of protected poles1
Over voltage category3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated impulse withstand voltage Uimp8kV
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Flush-mounted installationNo
Number of poles (total)1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS881001R0517 | S801C-K25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Rated insulation voltage Ui

500V

Current limiting class

3

Release characteristic

K

Rated current

25A

Rated voltage

440V

Pollution degree

3

Power loss

4.3W

Degree of protection (IP)

IP20

Explosion-proof

Width in number of modular spacings

4

Number of protected poles

1

Over voltage category

3

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated impulse withstand voltage Uimp

8kV

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Flush-mounted installation

Number of poles (total)

1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.