Technical specifications

Pollution degree3
Power loss7W
Connectable conductor cross section solid-core0 - 50mm²
Suitable for flush-mounted installationNo
Voltage typeAC
Rated insulation voltage Ui500V
Explosion-proofNo
Width in number of modular spacings2
Degree of protection (IP)IP20
Release characteristicB
Current limiting class3
Concurrently switching neutral conductorNo
Rated current20A
Rated voltage440V
Frequency50 - 60Hz
Number of protected poles2
Built-in depth82.5mm
Over voltage category4
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 70mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated impulse withstand voltage Uimp8kV
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS882001R0205 | S802C-B20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree

3

Power loss

7W

Connectable conductor cross section solid-core

0 .. 50mm²

Suitable for flush-mounted installation

Voltage type

AC

Rated insulation voltage Ui

500V

Explosion-proof

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Release characteristic

B

Current limiting class

3

Concurrently switching neutral conductor

Rated current

20A

Rated voltage

440V

Frequency

50 .. 60Hz

Number of protected poles

2

Built-in depth

82.5mm

Over voltage category

4

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 70mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated impulse withstand voltage Uimp

8kV

Number of poles (total)

2